A double membrane roof is an engineered gas-holding system consisting of an inner and outer membrane, creating an air-pressurized inter-membrane space.

Two 300 m³ Double Membrane Gas Holders Successfully Installed

November 17, 2026

Anaerobic treatment of pulp and paper wastewater produces biogas that can be used as supplementary boiler fuel or to generate electricity. A gas holder between the wastewater treatment system and the downstream equipment helps balance fluctuations in biogas production and demand.

At a paper mill in Xiaogan, Hubei Province, two 300 m³ double membrane biogas holders have been lifted into position, and the main installation work is complete. The stainless steel piping, pressure-regulating air blowers, valves, and other supporting equipment are also in place. With a combined storage capacity of 600 m³, the two holders will store biogas produced during anaerobic wastewater treatment and provide a buffer for downstream gas purification and energy recovery.

How do gas holders balance biogas production and demand?

Wastewater flow and organic loading at a paper mill can vary with production conditions, causing fluctuations in biogas output from the anaerobic treatment system. Boiler loads change with the mill’s heat demand, while generator sets may run on a separate schedule. When biogas production exceeds demand, the holders store the surplus. When downstream demand rises, the stored biogas can supplement the supply as long as reserves are available.

This buffer gives the wastewater treatment system and the downstream equipment more flexibility to operate at different rates. To size a gas holder for a paper mill, engineers consider the daily biogas production profile, downstream equipment loads, and the required buffer duration.

How do the three membranes work together?

The Xiaogan project uses freestanding double membrane gas holders. The bottom membrane and the perimeter anchoring and sealing system form a gas-tight base. As biogas enters the storage chamber, the inner membrane rises. It lowers as downstream equipment draws gas from the holder. Pressure-regulating air blowers supply air to the space between the inner and outer membranes, maintaining the shape of the outer membrane and helping keep the biogas pressure within the design operating range.

The gas holders, piping, and downstream equipment need to be sized and specified for the same gas supply conditions. When determining the holder’s operating pressure, engineers account for pressure losses in the gas piping, the pressure drop across the purification equipment, and the inlet pressure required by the boiler or generator set.

Qingdao Haiyue equipment and engineering support for biogas recovery

Qingdao Haiyue offers freestanding double membrane gas holders and tank-mounted double membrane gas holders. Freestanding units suit projects with a dedicated area for gas storage. For projects that integrate storage with an anaerobic digester, a tank-mounted unit can be selected based on the tank structure and operating conditions.

Haiyue can also supply biogas desulfurization and dehydration systems, biogas flares, and combined heat and power equipment. For paper mill wastewater projects, the boiler heat demand or power generation target, together with the expected biogas output and composition, helps determine storage capacity, gas treatment requirements, and connection points for downstream equipment.

If your paper mill is planning anaerobic wastewater treatment, partial replacement of conventional boiler fuels, or biogas power generation, send Qingdao Haiyue your estimated biogas production, downstream equipment specifications, and site layout. We can help size the gas holder and assess the equipment needed for your project.


Downlaod

+86-13021678731