Operational Performance
Double membrane gas holders operate reliably at pressures up to 30 mbar, with a precise fill level measurement system that monitors gas volume in real time. A constant air supply system maintains stable pressure between the inner and outer membranes. The combination of high-quality membrane materials and structural design ensures excellent resistance to wind and snow loads. Integrated safety devices – including overpressure valves and blow-off pipes – prevent downtime and ensure high operational reliability.
Economy & Installation
Double membrane gas holders offer low investment and operating costs, minimal maintenance expenses, and short construction time. Even with modest investment, very large storage volumes can be realised – delivering high economic efficiency.
Membrane & Materials
The membrane is high-frequency welded per DIN 18204-1, with heat applied directly at the seam to create a strong, uniform bond. The fabric is UV-stable, weatherproof, biogas-resistant, anti-mould treated, and flame-retardant (B1 class).